Global site
Back

Z-Flex T 690TA & 690TAY

Single-piece hydrophilic monofocal toric IOL for implantation into the capsular bag
Standard Powers:
0.0 D → +30.0 D (0.5 D steps)
Extreme Powers:
-10.0 D → -1.0 D (1.0 D steps)
+31.0 D → +35.0 D (1.0 D steps)
Material:
Copolymer of hydrophobic and hydrophilic monomers with 25% water content, UV absorber and optional Natural Yellow filter
RI:
1.46
Abbe No:
58
Optic Diameter:
6 mm
Overall Diameter:
13 mm
Optic Design:
Aspheric - Aberration Neutral
Convex-concave (-10.0 D → +5.0 D)
Biconvex (+5.5 D → +35.0 D)
Nominal A-constant:
118.9
Haptic Design:
Posterior vaulting C-loops with 0° angulation
PCO Prevention:
360° sharp edge
Estimated Incision Size:
2.2 - 2.4 mm
Shelf Life:
5 years after sterilization
Recommended Injector:
-10.0D → +35.0D & +1.0CYL → +4.5CYL: MEDJET MA 2.2
-10.0D → +30.0D & +1.0CYL → +10.0CYL: MEDJET MX 2.4 HB
+30.0D → +35.0D & +1.0CYL → +4.5CYL: MEDJET MX 2.4 HB

Downloads

O’h Eineachain R. - Z-Flex 690T(Y) Toric - O’h Eineachain R. New toric IOL – Good predictability and stability shown in initial results with new lens. EuroTimes. 2011 Jun;16(6):18.
June 6, 2011
Argay A, Vamosi P. - Z-Flex 690T(Y) Toric - The assessment of the impact of glistening on visual performance in relation to tear film quality. PLoS One. 2020 Oct 12;15(10):e0240440. doi: 10.1
October 12, 2020
Z-Flex T 690TA/TAY
September 12, 2022

Other products:

Bi-Flex T
Single piece, sterile, foldable acrylic aspheric hydrophilic posterior chamber intraocular lens (IOL) with UV blocker, optionally with blue light filter. The optic is monofocal toric. The IOL is non-preloaded, which has to be manually loaded into a compatible injector.
More details
Trifocal Toric Bi-Flex Liberty
Single piece, sterile, foldable acrylic aspheric hydrophilic posterior chamber intraocular lens (IOL) with UV blocker, optionally with blue light filter. The optic is trifocal toric. The IOL is non-preloaded, which has to be manually loaded into a compatible injector.
More details
1stQ AddOn® Refractive Toric
Single piece, sterile, foldable acrylic spheric hydrophilic posterior chamber intraocular lens (IOL) with UV blocker. The optic is monofocal toric. The IOL is non-preloaded and has to be manually loaded into a compatible injector.
More details
1stQ AddOn® Trifocal Toric
Single piece, sterile, foldable acrylic spheric hydrophilic posterior chamber intraocular lens (IOL) with UV blocker. The optic is trifocal toric. The IOL is non-preloaded and has to be manually loaded into a compatible injector.
More details

MEDICONTUR WORLDWIDE

Medicontur Orvostechnikai Kft. Hungary
Medicontur CZ s.r.o. Sales office Czech republic & Slovakia
Compagnia Italiana Oftalmologica scarl (CIO) Italy
SIA Industrialas Technologijas Latvia
ABJ-Vision Sp. z o.o Poland
Almaty Medical Products LLP Kazahstan
Heritage Medical Technology Jordan
Allied Medical and Scientific Co. Ltd. (AMICO) Syrian Arab Republic