Global site
Back

Trifocal Toric Bi-Flex Liberty 677MT & 677MTY

Single piece, sterile, foldable acrylic aspheric hydrophilic posterior chamber intraocular lens (IOL) with UV blocker, optionally with blue light filter. The optic is trifocal toric. The IOL is non-preloaded, which has to be manually loaded into a compatible injector.
Powers:
+8.0 D → +30.0 D (0.5 D steps)
Addition (at the IOL plane):
+3.5 D near
+1.75 D intermediate
Cylinders:
+1.0 D → +4.5 D (0.5 D steps)
+5.25 D → +6.0 D (0.75 D steps)*
*available above +10.0 D SEQ
Material:
Copolymer of hydrophobic and hydrophilic monomers with 25% water content, UV blocker and optional blue light filter
RI:
1.46
Abbe No:
58
Optic Diameter:
6 mm
Overall Diameter:
13 mm
Optic Design:
Aspheric - Aberration Neutral
Biconvex (+8.0 D → +35.0 D)
Nominal A-constant:
118.9
Diffractive Zone:
3 mm diameter diffractive array on the anterior surface utilizing EPS technology
Haptic Design:
Posterior vaulting fenestrated C-loops with 0° angulation
PCO Prevention:
360° sharp edge
Estimated Incision Size:
2.2 - 2.4 mm
Shelf Life:
5 years after sterilization
Recommended Injector:
Compatibility chart available:
https://medicontur.com/professionals/compatibility
LOADING GUIDE VIDEO

Downloads

Patient Information Flyer - Cataract
September 2, 2021
Liberty Lifestyle Patient Brochure
August 31, 2021
Liberty Informative Patient Brochure
September 2, 2021
Liberty Toric datasheet (677MTY)
March 13, 2024
IOL Portfolio
April 24, 2024

Other products:

Bi-Flex T
Single piece, sterile, foldable acrylic aspheric hydrophilic posterior chamber intraocular lens (IOL) with UV blocker, optionally with blue light filter. The optic is monofocal toric. The IOL is non-preloaded, which has to be manually loaded into a compatible injector.
More details
1stQ AddOn® Refractive Toric
Single piece, sterile, foldable acrylic spheric hydrophilic posterior chamber intraocular lens (IOL) with UV blocker. The optic is monofocal toric. The IOL is non-preloaded and has to be manually loaded into a compatible injector.
More details
1stQ AddOn® Trifocal Toric
Single piece, sterile, foldable acrylic spheric hydrophilic posterior chamber intraocular lens (IOL) with UV blocker. The optic is trifocal toric. The IOL is non-preloaded and has to be manually loaded into a compatible injector.
More details

MEDICONTUR WORLDWIDE

Medicontur Orvostechnikai Kft. Hungary
Medicontur CZ s.r.o. Sales office Czech republic & Slovakia
Compagnia Italiana Oftalmologica scarl (CIO) Italy
SIA Industrialas Technologijas Latvia
ABJ-Vision Sp. z o.o Poland
Almaty Medical Products LLP Kazahstan
Heritage Medical Technology Jordan
Allied Medical and Scientific Co. Ltd. (AMICO) Syrian Arab Republic